Heating and cooling One system for winter and summer

Air-to-Air Heat Pump Heating That Also Cools

An air-to-air heat pump warms your rooms in winter and cools them in summer, using the same split system as air conditioning. Aircova fits them in homes across London and the South East from £2,195, and each one gives about 3 to 4 kW of heat for every kW of electricity it uses.

  • F-Gas certified engineers
  • Fixed price in writing
  • Prices include VAT

Last updated and prices checked: October 2026

Winter illustration of a snowy house where an air-to-air heat pump outdoor unit draws heat from the cold air and a wall unit blows warm air into the living room
F-Gas certifiedQualified, registered engineers
Five leading brandsDaikin, Mitsubishi Electric, Fujitsu and more
Fixed pricesVAT included, confirmed in writing
Warranty registeredManufacturer terms confirmed in writing

See how it works

Air-to-air heat pumps in three short clips

How heat moves from outside air, what SCOP means, and how air-to-air differs from air-to-water.

Air-to-air heat pump: heat from outside air
Air-to-air heat pump: heat from outside airAn air-to-air heat pump moves heat from outdoor air into your room.
Air-to-air heat pumps: SCOP explained
Air-to-air heat pumps: SCOP explainedSCOP is the seasonal efficiency of a heat pump. A SCOP of 4 means about 4 units of heat per unit of electricity.
Air-to-air or air-to-water heat pump
Air-to-air or air-to-water heat pumpThe main differences between air-to-air and air-to-water heat pumps.

How it works

What is an air-to-air heat pump?

An air-to-air heat pump is a split system that takes warmth from the outside air and blows it into your rooms through an indoor unit. It is the same equipment as home air conditioning, run in reverse. Aircova fits them as one system that heats in winter and cools in summer.

That is why installers also call it reverse cycle air conditioning. A small valve inside the outdoor unit swaps the direction the refrigerant flows. In cooling mode, heat is pulled out of the room and dumped outside. In heating mode, the same pipes carry heat the other way.

The kit has three parts. An outdoor unit holds the compressor and a large coil. An indoor unit sits high on the wall, or hidden in a ceiling, and blows warm air across the room. Insulated copper pipes, a power cable and a condensate drain join the two through a 65mm hole in the wall.

How it heats, in plain words

Refrigerant boils at a very low temperature, far below freezing. That is the trick that lets it soak up warmth from cold air.

  1. Collect. Cold liquid refrigerant in the outdoor coil absorbs warmth from the outside air and turns to gas.
  2. Compress. The inverter compressor squeezes the gas, which makes it much hotter.
  3. Release. Hot gas flows to the indoor unit, where a fan blows room air across the warm coil.
  4. Repeat. The refrigerant cools, turns back to liquid, and returns outside to collect more heat.

The electricity runs the compressor and fans. It does not make the heat itself, it moves heat that is already outside. That is why one unit of electricity can deliver three or four units of warmth indoors.

Every unit we fit runs on R32 refrigerant, which has a lower global warming impact than the older R410A gas, and that matters if you are replacing an older unit. Fitting and servicing any system that holds refrigerant needs an F gas qualification, as the government guidance on F gas sets out. All Aircova engineers hold it, and you can see our F gas certification and what we do not hold yet.

Diagram of an outdoor unit collecting heat from cold outside air and pumping it through refrigerant pipes to an indoor wall unit that blows warm air into the room
The outdoor unit collects heat from the air, even on cold days, and sends it indoors through insulated pipes.

Efficiency

SCOP explained, and how it copes with UK winters

Heating efficiency is shown as SCOP, the seasonal coefficient of performance. It is the total heat a unit gives out across a heating season, divided by the electricity it uses. A higher number means cheaper heat.

The wall units we install from Daikin, Mitsubishi Electric and Fujitsu are rated at a SCOP of around 4. In practice that means about 3 to 4 kW of heat for every kW of electricity, depending on the weather. A plug-in fan heater, a panel heater or a storage heater turns 1 kW of electricity into just 1 kW of heat.

The labels to compare

SCOP
Heating efficiency over a season. Around 4 on the units we fit.
SEER
Cooling efficiency over a summer. Many units are rated A++.
kW output
How much heat the unit can give. A 3.5kW unit suits most lounges.

Heat out for each kW in

Electric heaters
  • 1 kW in, 1 kW of heat out
  • Storage heaters lose heat by evening
  • No cooling
Heat pump
  • 1 kW in, 3 to 4 kW of heat out
  • Heat when you need it
  • Cools in summer

Does it work in a cold UK winter?

Yes. Modern inverter units keep heating well below freezing, which covers the cold snaps London and the South East get. Efficiency does drop as the outside air gets colder, because there is less warmth to collect.

On frosty mornings the outdoor coil can ice up. The unit runs a short defrost cycle every so often, and you may see a little steam rise from the outdoor unit. Heat into the room pauses for a few minutes, then carries on.

Sizing is what makes the difference in January. We size each indoor unit for heating as well as cooling, based on the room, its windows and how well it holds heat. A unit sized only for summer can struggle on the coldest days. Our BTU calculator gives a first idea, and 1kW is about 3,412 BTU/h.

Illustration of a frosted outdoor unit still heating below freezing, with a short defrost cycle on a frosty morning
Modern units keep heating below freezing, with short defrost cycles on frosty mornings.

Know the difference

Air-to-air vs air-to-water heat pumps

Both types take warmth from outside air. The difference is where the heat goes. An air source heat pump of the air-to-water kind heats water for radiators and a hot water cylinder. An air-to-air system heats the air in each room directly.

Air-to-air and air-to-water heat pumps compared
FeatureAir-to-airAir-to-water
How heat reaches youWarm air from indoor unitsRadiators or underfloor heating
Hot water for tapsNoYes, with a cylinder
Cooling in summerYesNot on most systems
Space needed indoorsIndoor unit on the wallCylinder cupboard, often larger radiators
Heat-up speedRoom warms in minutesSlow and steady
Boiler Upgrade Scheme grant£2,500 category, but no installer is MCS certified to claim it yet£7,500 through an MCS installer

Hot water with an air-to-air system

An air-to-air system does not heat your hot water, and it does not connect to radiators. So you still need another way to heat water.

Some homes keep a gas boiler for hot water and showers, which rules out any grant. Others use an electric immersion heater, an electric shower, a point of use heater at the sink or a separate hot water heat pump.

When air-to-water is the better choice

If you have a house full of radiators and a gas boiler that heats everything, an air-to-water system may suit you better. It replaces the boiler completely. It is also a bigger job, often with new radiators and a hot water cylinder.

If that is what your home needs, we will say so at the survey, rather than sell you the wrong product.

Pros and cons

What are the disadvantages of an air-to-air heat pump?

An air-to-air heat pump does not heat hot water or radiators, and it only warms rooms that have an indoor unit. Each indoor unit is visible on the wall or ceiling. Output falls in very cold weather and warm air can feel drier. The £2,500 grant also needs an installer MCS certified for air-to-air, and there are none yet.

Pros and cons at a glance
ProsCons
Heats in winter and cools in summer from one systemNo hot water and no link to radiators
About 3 to 4 kW of heat for each kW of electricityOnly rooms with an indoor unit are heated
Rooms warm in minutes, each with its own controlIndoor units are on show, on the wall or ceiling
One room is usually fitted in a day, with no new radiators or cylinderOutput and efficiency fall on the coldest days
Lower upfront cost than an air-to-water systemThe grant cannot be claimed until MCS certifies air-to-air installers

The Energy Saving Trust puts a typical installed cost at about £1,900 for a single room and £3,700 for a three bedroom semi. The outdoor unit also makes some noise, typically 45 to 50dB, so we plan where it goes with your neighbours in mind. Most of these downsides are about fit, not quality, which is why we check each room at the survey.

Comparison illustration: a storage or panel heater turns 1 kW of electricity into 1 kW of heat, an air-to-air heat pump turns it into 3 to 4 kW, about 6.6p per kWh of heat

Electric heating upgrade

Replacing storage heaters and panel heaters

If you want to replace storage heaters or panel heaters, heat pump air conditioning makes the biggest difference. Those heaters give 1 kW of heat per kW of electricity. A heat pump gives three to four.

3 to 4kW of heat for every kW of electricity
6.6pper kWh of heat at SCOP 4
1 dayto fit a single room in most homes

At the Ofgem cap of 26.32p per kWh for October to December 2026, a panel heater costs 26.3p for each kWh of heat. A heat pump at SCOP 4 costs about 6.6p. Storage heaters on a night rate cost less than panel heaters, but a heat pump still wins at any night rate above about 6.6p.

Storage heaters also run on a timer. They charge overnight and are often cold by the time you get home. An indoor unit heats the room when you switch it on, from the remote or a phone app.

We take the old heaters off the wall, cap the supply safely, and fit the new indoor units in their place. Each room gets its own temperature setting. A full breakdown of bills sits in our air conditioning running costs guide.

Is it right for you

Homes it suits best

Air conditioning for heating works best where rooms need warmth quickly and there is no wet central heating, or where the existing heating is expensive to run. These are the homes it usually suits best. It also works well for heating and cooling a conservatory, which is too cold in winter and too hot in summer.

Illustration of a block of flats where an old storage heater is swapped for a wall-mounted air-to-air heat pump

Flats on electric heating

Many London flats have no gas supply at all. A wall unit replaces panel heaters, and the outdoor unit often sits on the balcony, with freeholder consent.

Units for flats
Illustration of a house with a single-storey rear extension heated by a wall-mounted air-to-air heat pump

Lofts and extensions

A new loft or rear extension is often too far for the boiler to reach. One unit heats it in winter and keeps it cool under the roof in summer.

Loft conversions
Illustration of a cosy bedroom warmed by a wall-mounted air-to-air heat pump while snow falls outside the window

Bedrooms

Quiet modes from about 19dB on some indoor units let you warm a bedroom before bed without the hum of a fan heater.

Bedroom units
  • Homes heated by storage heaters, panel heaters or plug-in heaters
  • Garden rooms and home offices that need heat all winter, as our garden room air conditioning guide explains
  • Houses that keep a gas boiler for hot water but want cheaper room heat (no grant in this case)
  • Rooms that overheat in summer and feel cold in winter
  • Older terraces where new radiator pipework would mean lifting floors

It is less of a fit as the only heating in a large, poorly insulated house with no indoor unit in some rooms. Bathrooms and hallways are usually left out, so they need another heat source. We talk this through honestly at the survey.

Insulation comes first. Loft insulation and draught proofing cut the heat each room loses, so a smaller unit does the job and costs less to run.

Grant and price

Grant status and what it costs

Since 21 July 2026, the Boiler Upgrade Scheme run by Ofgem has listed £2,500 for air-to-air systems in England and Wales. The heat pump has to replace fossil fuel or electric heating and cover all of the home’s space heating, so keeping a boiler rules it out.

The grant needs an MCS installer certified for air-to-air. None are certified yet, Aircova included. We price without it and tell you when it can apply. Our page on the air-to-air heat pump grant explains who will be able to claim.

How much does it cost?

A single room system starts from £2,195 fitted, and two rooms on a multi-split start from £3,995, both including VAT. Our page on air-to-air heat pump prices sets out the cost by room and by kW.

For every system type, size and brand, see our air conditioning cost guide. Or see your fixed price online in about two minutes.

Prices last checked: October 2026. Prices include up to 3 metres of pipe per indoor unit, a bracket, electrical connection and commissioning. Longer pipe runs, scaffolding and consumer unit upgrades are priced at the survey.

Illustration of a fixed price quote document and a pound coin, noting that no grant is built into the price
Our fixed prices never include a grant, so your quote does not depend on one.

System choices

Choosing a system, fitting day and servicing

Every split system gives you air conditioning heating and cooling from one outdoor unit. The choice is about how many rooms you want to heat and how much you want on show.

Wall-mounted

Best for one room

One indoor unit linked to one outdoor unit. A 2.5kW unit suits a bedroom up to about 20m², and 3.5kW suits most lounges.

Multi-split

Best for two to five rooms

Two to five indoor units share one outdoor unit. Each room has its own control, so you only heat the rooms you use.

Ducted

Best for renovations

The indoor unit hides in the loft or a ceiling void, and warm air comes through slim grilles. It needs about 25 to 30cm of space.

Floor-standing and cassette units

Wall units are the usual choice, but not the only one. A floor-standing console sits low on the wall like a radiator, which suits loft rooms with sloping ceilings or walls full of windows. A ceiling cassette sits flush in a suspended ceiling and spreads air four ways across a large open plan room. We price both at the survey.

How installation works

We handle the whole job, from survey to handover. Most single rooms take one day, often 5 to 7 hours. A two or three room multi-split takes two to three days.

  1. Survey. We measure each room, check heat loss, and plan the pipe run and outdoor unit spot.
  2. Written quote. You get the models, the fixed price and the payment terms in writing.
  3. Fitting. We mount both units, core drill the wall and run pipe, cable and drain.
  4. Commissioning. A nitrogen pressure test and vacuum, then refrigerant release and full testing.
  5. Handover. We set up heating mode, show you the app and register your warranty.

Most single units on houses need no planning permission. Flats, listed buildings and conservation areas often need consent, so check with your council. Our planning permission guide covers the common cases.

Servicing for year-round use

A system used for heating all winter and cooling all summer works hard. A yearly service cleans the filters and coil, checks refrigerant pressure and clears the condensate drain.

We register the manufacturer warranty. The term depends on the brand and model and is confirmed in writing, and some extended terms need yearly servicing. Book a yearly heat pump service with us each autumn, before the heating season starts.

We fit Daikin, Mitsubishi Electric, Fujitsu, Toshiba and Panasonic, with Samsung, LG and Hitachi on request, subject to availability. This page covers the heating side, while our main page on air conditioning installation covers cooling.

Illustration of an indoor unit checked with a spirit level and its pipe hole sealed through the brick wall so it drains properly and lets in no draughts
Engineers level the indoor unit and seal the wall hole to stop draughts in winter.

FAQs

Heat pump questions

Is an air-to-air heat pump the same as air conditioning?

Yes, in most cases it is the same equipment. A modern split air conditioner is a heat pump that can run in either direction. In summer it moves heat out of your room, and in winter it reverses and moves heat in from outside. The term heat pump air conditioning describes exactly this. Some cheap portable units only cool, so check the spec for a heating mode and a SCOP rating. With heating and cooling from the same indoor unit, there is no fan heater in winter and no portable unit in summer to store.

Can an air-to-air heat pump heat a whole house?

It can, if every room you want warm has an indoor unit. A multi-split runs up to five indoor units from one outdoor unit, which covers many flats and small houses. Bathrooms and hallways are usually left out, so they need a towel rail or small heater. In larger homes, some owners use it alongside an existing boiler, without the grant.

Does an air-to-air heat pump provide hot water?

No. An air-to-air system only heats the air in your rooms. It does not heat a hot water cylinder or radiators. Some homes keep their boiler for hot water, which rules out the grant, or use an immersion heater, an electric shower or a point of use heater. If you need hot water from a heat pump, an air-to-water system is the type to look at.

Do air-to-air heat pumps work when it is below freezing?

Yes. Modern inverter units keep heating well below 0°C, which covers a normal London or South East winter. Output and efficiency fall as the air gets colder, so correct sizing matters. On frosty days the outdoor unit runs short defrost cycles, and heat pauses for a few minutes before it starts again.

Can I replace storage heaters with air conditioning?

Yes, and it is one of the best upgrades for an all-electric home. Storage heaters give 1 kW of heat for each kW of electricity, while reverse cycle air conditioning gives about 3 to 4 kW. You also get heat when you need it, not overnight. We remove the old heaters, make the supply safe and fit indoor units in the same rooms.

What does SCOP mean on a heat pump?

SCOP stands for seasonal coefficient of performance. It tells you how much heat a unit gives out over a whole heating season for each unit of electricity it uses. A SCOP of 4 means about 4 kW of heat per kW of power on average. The wall units we fit from the leading brands are rated at around 4.

Is warm air heating from a wall unit comfortable?

Yes, when the indoor unit is placed well. We fit it high on the wall and set the louvres so warm air spreads across the room, not onto your sofa or bed. Rooms warm up in minutes, much faster than radiators. Some people find the air drier than radiator heat, so a plant or small humidifier can help.

Do I need an MCS installer for an air-to-air heat pump?

Only to claim the grant. The £2,500 Boiler Upgrade Scheme grant is paid only through an installer MCS certified for air-to-air, and MCS says none are certified yet, Aircova included. You do not need MCS to have a system fitted. Anyone fitting a system that holds refrigerant must hold an F gas qualification, which our engineers do. Our prices never include the grant.

Is an air-to-air heat pump an air source heat pump?

Yes. It is one of the two types of air source heat pump, as both take heat from the outside air. Most people who search for an air source heat pump mean the air-to-water type, which heats radiators and a hot water cylinder. The air-to-air type warms room air through indoor units instead, and it can cool in summer too.

Can I have a heat pump fitted in a flat?

Usually, yes. Most flats need written consent from the freeholder or managing agent before an outdoor unit goes on the building. A balcony is often the best place for it. We supply the spec sheet, noise figures and a marked up photo to send with your request, and we fit once consent is in.

Get your fixed price

Tell us which rooms you want to heat and cool, and how they are heated now. We will call you with a fixed price, and our prices never include a grant. No pressure and no obligation.

  • Reply within an hour
  • Free home survey
  • Price confirmed in writing

Prefer to talk? Call 07403 664179
Monday to Friday 8am to 6pm, Saturday 9am to 5pm

Aircova quick quote

We only use your details to prepare your quote. See our privacy policy.